{"id":4860,"date":"2025-11-07T11:50:36","date_gmt":"2025-11-07T03:50:36","guid":{"rendered":"https:\/\/www.yifuproducts.com\/?p=4860"},"modified":"2025-11-05T11:01:31","modified_gmt":"2025-11-05T03:01:31","slug":"what-does-1u-or-2u-mean-on-a-server-a-simple-guide-for-rack-planning","status":"publish","type":"post","link":"https:\/\/www.yifuproducts.com\/fr\/what-does-1u-or-2u-mean-on-a-server-a-simple-guide-for-rack-planning\/","title":{"rendered":"Que signifie 1U ou 2U sur un serveur? Un guide simple pour la planification des racks"},"content":{"rendered":"<p>Si vous avez d\u00e9j\u00e0 essay\u00e9 de construire ou d\u2019organiser un rack de serveurs, vous avez probablement rencontr\u00e9 cette lettre myst\u00e9rieuse \u00ab U \u00bb. Elle appara\u00eet partout \u2013 1U, 2U, 4U \u2013 et tout le monde en informatique semble supposer que vous savez juste ce que cela signifie. Mais si vous \u00eates nouveau \u00e0 des syst\u00e8mes de rack, le terme peut \u00eatre confus. Alors clarifions cela avant que votre prochaine installation de centre de donn\u00e9es ne se transforme en un jeu de Tetris.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-large wp-image-4854\" src=\"https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/What-Does-1U-or-2U-Mean-on-a-Server-A-Simple-Guide-for-Rack-Planning-1024x683.webp\" alt=\"Que signifie 1U ou 2U sur un serveur Un guide simple pour la planification de rack\" width=\"800\" height=\"534\" srcset=\"https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/What-Does-1U-or-2U-Mean-on-a-Server-A-Simple-Guide-for-Rack-Planning-1024x683.webp 1024w, https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/What-Does-1U-or-2U-Mean-on-a-Server-A-Simple-Guide-for-Rack-Planning-300x200.webp 300w, https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/What-Does-1U-or-2U-Mean-on-a-Server-A-Simple-Guide-for-Rack-Planning-768x512.webp 768w, https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/What-Does-1U-or-2U-Mean-on-a-Server-A-Simple-Guide-for-Rack-Planning-18x12.webp 18w, https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/What-Does-1U-or-2U-Mean-on-a-Server-A-Simple-Guide-for-Rack-Planning-600x400.webp 600w, https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/What-Does-1U-or-2U-Mean-on-a-Server-A-Simple-Guide-for-Rack-Planning.webp 1141w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>En bref, \u00ab U \u00bb est la fa\u00e7on dont nous mesurons les bo\u00eetiers de montage de rack verticalement. Le choix entre 1U, 2U ou 4U n\u2019est pas seulement une question de hauteur \u2013 il affecte le refroidissement, le bruit, le c\u00e2blage et m\u00eame la quantit\u00e9 de votre \u00e9quipe pendant la maintenance.<\/p>\n<p>Chez IFSTAR, nous passons beaucoup de temps \u00e0 y r\u00e9fl\u00e9chir. Nous concevons <a style=\"text-decoration: underline;\" href=\"https:\/\/www.yifuproducts.com\/fr\/rack-cases\/2u\/\"><strong>Cas de montage en rack 2U<\/strong><\/a> utilis\u00e9s dans les centres de donn\u00e9es, les usines et les salles de contr\u00f4le - des endroits o\u00f9 l'espace est serr\u00e9 et les temps d'arr\u00eat co\u00fbtent de l'argent r\u00e9el.<\/p>\n<h2 id=\"what-does-1u-or-2u-mean\"><strong><strong>Que signifie 1U ou 2U ?<\/strong><\/strong><\/h2>\n<h3 id=\"definition-of-rack-unit-u\"><strong><strong>D\u00e9finition de Rack Unit (U)<\/strong><\/strong><\/h3>\n<p>Une unit\u00e9 de rack (abr\u00e9viation de \u00ab U \u00bb) \u00e9quivaut \u00e0 1,75 pouces, ou environ la largeur de votre index et de votre doigt moyen empil\u00e9s ensemble. C\u2019est la hauteur verticale que chaque pi\u00e8ce d\u2019engrenage prend dans un \u00e9tag\u00e8re de 19 pouces, qui est la largeur standard mondiale de 19 pouces (482,6 mm).<\/p>\n<p>Lorsque vous entendez \u00ab 1U rack mount case \u00bb, cela signifie que le cas prend l\u2019une de ces unit\u00e9s.  \"2U\" est deux fois plus, environ 3,5 pouces ta ll. Cela semble simple, mais ce petit nombre contr\u00f4le tout, du flux d'air \u00e0 la port\u00e9e du c\u00e2ble.<\/p>\n<h3 id=\"u-vs-2u-the-real-world-difference\"><strong><strong>1U vs 2U - La diff\u00e9rence du monde r\u00e9el<\/strong><\/strong><\/h3>\n<p>Soyons r\u00e9els - sur le papier, 1U et 2U n'ont pas l'air si diff\u00e9rent. Mais quiconque a d\u00e9j\u00e0 racked les deux sait que pouce suppl\u00e9mentaire et trois quarts rend la vie beaucoup plus facile.<\/p>\n<p>Un bo\u00eetier de montage en rack 1U est \u00e9l\u00e9gant, compact et souvent une douleur \u00e0 travailler \u00e0 l'int\u00e9rieur. Vous devrez probablement utiliser des refroidisseurs \u00e0 profil bas et orienter soigneusement les c\u00e2bles comme un chirurgien.<br \/>\nUn bo\u00eetier de montage en rack 2U, d'autre part, semble spacieux - assez d'espace pour les ventilateurs appropri\u00e9s, des unit\u00e9s d'alimentation duales et une disposition dans laquelle vos doigts peuvent r\u00e9ellement s'adapter.<\/p>\n<p>Si vous choisissez le meilleur \u00e9tui de montage en rack 1U pour les serveurs, pensez au bruit, au refroidissement et \u00e0 la fr\u00e9quence \u00e0 laquelle vous devrez \u00e9changer des disques. Les bo\u00eetiers \u00e9troits fonctionnent plus chauds et sont moins indulgents quand un ventilateur \u00e9choue.<\/p>\n<p>En th\u00e9orie, un rack 42U peut accueillir quarante-deux serveurs 1U ou vingt-et-un unit\u00e9s 2U. En r\u00e9alit\u00e9, personne ne l'emballe \u00e0 100%. Vous aurez besoin de laisser un peu d\u2019espace respiratoire. L'air chaud n'aime pas les math\u00e9matiques - il s'\u00e9l\u00e8ve que votre plan d'\u00e9tag\u00e8re soit d'accord ou non.<\/p>\n<h2 id=\"which-one-should-you-choose-1u-or-2u\"><strong><strong>Lequel choisir : 1U ou 2U ?<\/strong><\/strong><\/h2>\n<h3 id=\"u-rack-case-small-but-mighty\"><strong><strong>1U Rack Case: Petit mais puissant<\/strong><\/strong><\/h3>\n<p>Les syst\u00e8mes 1U sont tout au sujet de la densit\u00e9. Si vous essayez de remplir autant de calcul que possible dans un seul armoire \u2013 comme l\u2019h\u00e9bergement web, les t\u00e2ches r\u00e9seau l\u00e9g\u00e8res ou la surveillance simple \u2013 1U a du sens.<\/p>\n<p>Ils sirotent de l'\u00e9nergie, restent relativement silencieux et sont parfaits pour les armoires \u00e0 distance. Mais il y a un probl\u00e8me : le refroidissement.<\/p>\n<p>Une conception intelligente de refroidissement du coffre rack 1U utilise des ventilateurs frontaux forts, des panneaux ventil\u00e9s et des chemins de chaleur \u00e9troits. Un ventilateur bouch\u00e9 ou poussi\u00e9reux et la temp\u00e9rature de votre processeur monte plus vite que vous ne le pensez.<\/p>\n<h3 id=\"u-rack-case-more-space-more-options\"><strong><strong>2U Rack Case: plus d'espace, plus d'options<\/strong><\/strong><\/h3>\n<p>Les unit\u00e9s 2U respirent plus facilement. La hauteur suppl\u00e9mentaire permet de disposer de ventilateurs plus grands, d'un meilleur d\u00e9bit d'air et de plus d'entra\u00eenements. Vous pouvez m\u00eame installer des GPU ou des alimentations redondantes.<\/p>\n<p>Si votre syst\u00e8me g\u00e8re des t\u00e2ches d'IA ou de stockage, un coffre rack 2U avec une alimentation redondante est un incontournable. Il continue de fonctionner m\u00eame si une unit\u00e9 \u00e9lectrique meurt - petit d\u00e9tail, mais lorsque votre ligne de production d\u00e9pend du temps de fonctionnement, ce d\u00e9tail compte.<\/p>\n<table style=\"width: 100%;\">\n<colgroup>\n<col style=\"width: 30%;\" \/>\n<col style=\"width: 35%;\" \/>\n<col style=\"width: 33%;\" \/> <\/colgroup>\n<thead>\n<tr>\n<th style=\"text-align: left;\"><strong>Outils, \u00e9quipement, \u00e9quipement de construction, travaux de site Acc. stockage\/transport<\/strong><\/th>\n<th style=\"text-align: left;\"><strong>\u00c9tui de rack 1U<\/strong><\/th>\n<th style=\"text-align: left;\"><strong>\u00c9tui de rack 2U<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\">Hauteur<\/td>\n<td style=\"text-align: left;\">1,75 po \/ 44,45 mm<\/td>\n<td style=\"text-align: left;\">3,5 po \/ 88,9 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">Parfait pour les amateurs de drones, les photographes, les vid\u00e9ographes et les professionnels qui ont besoin d'une protection fiable pour leur \u00e9quipement.<\/td>\n<td style=\"text-align: left;\">Tr\u00e8s haut<\/td>\n<td style=\"text-align: left;\">Mod\u00e9r\u00e9<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">refroidissement<\/td>\n<td style=\"text-align: left;\">Limit\u00e9<\/td>\n<td style=\"text-align: left;\">Excellent<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">Flexibilit\u00e9 des composants<\/td>\n<td style=\"text-align: left;\">serr\u00e9<\/td>\n<td style=\"text-align: left;\">Flexible<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\">Utilisation typique<\/td>\n<td style=\"text-align: left;\">\u00c9quipement de r\u00e9seau, pare-feu<\/td>\n<td style=\"text-align: left;\">Serveurs AI, tableaux de stockage<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 id=\"common-rack-heights-and-capacities\"><strong><strong>Hauteurs et capacit\u00e9s de rack communes<\/strong><\/strong><\/h2>\n<h3 id=\"what-is-a-42u-rack\"><strong><strong>Qu'est-ce qu'un rack 42U?<\/strong><\/strong><\/h3>\n<p>Le rack 42U est comme la norme or dans la plupart des centres de donn\u00e9es. Il mesure environ 2 m\u00e8tres de haut - un peu plus haut que la plupart des gens - et offre assez d'espace pour des configurations informatiques s\u00e9rieuses.<\/p>\n<p>Dimensions typiques ? Environ 2000 mm de haut, 600 mm de large et 1000 mm de profondeur. Vous pourriez y empiler 42 serveurs \u00e0 une seule unit\u00e9, bien que dans le monde r\u00e9el, les quelques unit\u00e9s inf\u00e9rieures contiennent g\u00e9n\u00e9ralement des syst\u00e8mes UPS lourds ou des PDU.<\/p>\n<p>Lorsque vous planifiez une mise en page de rack case 42U, rappelez-vous: le flux d'air et l'acc\u00e8s au service sont d'abord. Il est pr\u00e9f\u00e9rable de perdre quelques fentes que de perdre tout un rack en raison de l\u2019accumulation de chaleur.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-4857\" src=\"https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/rack-mount-server-1024x530.webp\" alt=\"serveur de montage rack\" width=\"800\" height=\"414\" srcset=\"https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/rack-mount-server-1024x530.webp 1024w, https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/rack-mount-server-300x155.webp 300w, https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/rack-mount-server-768x397.webp 768w, https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/rack-mount-server-18x9.webp 18w, https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/rack-mount-server-600x310.webp 600w, https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/rack-mount-server.webp 1115w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2 id=\"power-and-cooling-the-part-nobody-loves-but-everyone-needs\"><strong><strong>Puissance et refroidissement - la partie que personne n'aime mais que tout le monde a besoin<\/strong><\/strong><\/h2>\n<p>Chaque serveur suppl\u00e9mentaire ajoute des watts, et les watts se transforment en chaleur.<\/p>\n<p>Lorsque nous installons des \u00e9tag\u00e8res pour les clients, nous laissons g\u00e9n\u00e9ralement une marge de 20% de puissance par armoire. Ce n\u2019est pas de la science-fiction, c\u2019est juste la s\u00e9curit\u00e9. Les syst\u00e8mes tirent rarement pleine charge en continu, mais quand ils le font, vous serez heureux pour le tampon.<\/p>\n<p>Les racks denses remplis de bo\u00eetiers 1U peuvent facilement atteindre une puissance de 5 \u00e0 7 kW. Sans refroidissement solide, c\u2019est un chauffage d\u2019espace.<br \/>\nVoil\u00e0 o\u00f9 la mise en page intelligente aide: alternez les chemins d'admission et d'\u00e9chappement, laissez un panneau vide de 1U tous les quelques serveurs et gardez les c\u00e2bles en ordre.<\/p>\n<p>Nous avons une fois mesur\u00e9 deux \u00e9tag\u00e8res identiques - l'une emball\u00e9e en haut, l'autre avec de petits espaces d'air - le second fonctionnait environ 6 \u00b0 C plus froid en moyenne. C\u2019est l\u2019efficacit\u00e9 libre.<\/p>\n<h2 id=\"how-to-choose-the-right-rack-mount-case\"><strong><strong>Comment choisir le bon Rack Mount Case<\/strong><\/strong><\/h2>\n<h3 id=\"check-depth-and-compatibility\"><strong><strong>V\u00e9rifiez la profondeur et la compatibilit\u00e9<\/strong><\/strong><\/h3>\n<p>Les \u00e9tag\u00e8res sont disponibles en diff\u00e9rentes profondeurs, g\u00e9n\u00e9ralement de 600 \u00e0 1000 mm. V\u00e9rifiez toujours la profondeur du bo\u00eetier plus la longueur du rail avant de commander. Rien ne g\u00e2che votre journ\u00e9e comme d\u00e9couvrir que votre bo\u00eetier s'\u00e9l\u00e8ve un pouce au-del\u00e0 de la porte arri\u00e8re.<\/p>\n<p>Pour les constructions sp\u00e9cialis\u00e9es, a <a style=\"text-decoration: underline;\" href=\"https:\/\/www.yifuproducts.com\/fr\/rack-cases\/\"><strong>bo\u00eetier de montage de rack de profondeur personnalis\u00e9<\/strong><\/a> Ils s'adaptent \u00e0 de longues cartes GPU, \u00e0 des modules de commande ou \u00e0 des unit\u00e9s alimentaires profondes sans lacunes g\u00eanantes.<\/p>\n<h3 id=\"material-and-cooling-details\"><strong><strong>D\u00e9tails du mat\u00e9riau et du refroidissement<\/strong><\/strong><\/h3>\n<p>Le choix des mat\u00e9riaux change tout. Les bo\u00eetiers en aluminium sont plus l\u00e9gers et perdent de la chaleur rapidement. Les aciers sont plus robustes - id\u00e9aux pour les espaces industriels avec des vibrations ou de la poussi\u00e8re.<\/p>\n<p>Rechercher :<\/p>\n<ul>\n<li>Fronts ou vents lat\u00e9raux perfor\u00e9s<\/li>\n<li>Plateaux de ventilateur en option<\/li>\n<li>Filtre si votre environnement est poussi\u00e9reux<\/li>\n<\/ul>\n<p>Une petite chose comme la direction du flux d'air compte. J'ai vu des installations o\u00f9 la moiti\u00e9 des ventilateurs soufflaient en avant et le reste en arri\u00e8re - il a transform\u00e9 le rack en un m\u00e9langeur \u00e0 convection.<\/p>\n<h3 id=\"customization-options\"><strong><strong>OEM personnalisable<\/strong><\/strong><\/h3>\n<p>IFSTAR construit des bo\u00eetiers sur mesure pour diff\u00e9rentes industries, des t\u00e9l\u00e9communications \u00e0 l'automatisation industrielle.<\/p>\n<p>Besoin de votre logo sur le panneau avant ou de d\u00e9coupes E\/S sp\u00e9ciales ? Pas de probl\u00e8me.<br \/>\nVous voulez un rev\u00eatement en poudre qui correspond \u00e0 la couleur de votre marque? Nous l\u2019avons fait aussi.<\/p>\n<p>Nous fournissons \u00e9galement des bo\u00eetiers de montage en \u00e9tag\u00e8re pour les syst\u00e8mes de contr\u00f4le industriels - construits en r\u00e9sistance, test\u00e9s aux vibrations et pr\u00eats \u00e0 \u00eatre utilis\u00e9s 24 heures sur 24.<\/p>\n<p>Consultez IFSTAR si vous cherchez des \u00e9tuis de rack 1U ou 2U sp\u00e9cifiques, ou si vous voulez en parler <a style=\"text-decoration: underline;\" href=\"https:\/\/www.yifuproducts.com\/fr\/support\/\"><strong>supports OEM personnalis\u00e9s<\/strong><\/a>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-4856\" src=\"https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/rack-mount-server-case.webp\" alt=\"Rack mount bo\u00eetier serveur\" width=\"648\" height=\"579\" srcset=\"https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/rack-mount-server-case.webp 648w, https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/rack-mount-server-case-300x268.webp 300w, https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/rack-mount-server-case-13x12.webp 13w, https:\/\/www.yifuproducts.com\/wp-content\/uploads\/2025\/11\/rack-mount-server-case-600x536.webp 600w\" sizes=\"(max-width: 648px) 100vw, 648px\" \/><\/p>\n<h2 id=\"conclusion\"><strong><strong>Id\u00e9al pour: cam\u00e9ras reflex num\u00e9riques, cam\u00e9ras sans miroir, drones, cam\u00e9ras d'action, lentilles, disques durs et \u00e9lectronique sensible.<\/strong><\/strong><\/h2>\n<p>Savoir ce que signifie \"1U\" ou \"2U\" peut sembler banal, mais en pratique, c'est la diff\u00e9rence entre une installation lisse et une installation transpir\u00e9e. Un \u00e9tag\u00e8re bien planifi\u00e9 est plus silencieux, plus frais et plus facile \u00e0 r\u00e9parer \u00e0 2 heures du matin lorsque quelque chose \u00e9choue - parce qu'il le fait toujours.<\/p>\n<p>Que vous choisissiez des configurations 1U denses ou des configurations 2U flexibles, le bon bo\u00eetier de montage en rack garde tout s\u00e9curis\u00e9, frais et utile pendant des ann\u00e9es.<\/p>\n<p>Nous en avons construit des centaines, et une le\u00e7on reste: un bon flux d\u2019air et un peu d\u2019espace suppl\u00e9mentaire ne sortent jamais de la mode.<\/p>\n<h2 id=\"faq\"><strong><strong>Petites bo\u00eetes \u2013 Yifu<\/strong><\/strong><\/h2>\n<p><strong>Q: Qu'est-ce que signifie \"U\" dans les bo\u00eetiers de montage en rack?<\/strong><\/p>\n<p><strong>bo\u00eete de toit dure(2)<\/strong> C\u2019est l\u2019abr\u00e9viation de \u00ab rack unit \u00bb, la mesure de la hauteur verticale dans un rack standard de 19 pouces (1U = 1,75 pouces).<\/p>\n<p><strong>Q : Combien de serveurs 1U ou 2U peuvent \u00eatre install\u00e9s dans un rack 42U ?<\/strong><\/p>\n<p><strong>bo\u00eete de toit dure(2)<\/strong> Jusqu'\u00e0 42 \u00d7 1U ou 21 \u00d7 2U, selon les espaces de refroidissement et la gestion du c\u00e2ble.<\/p>\n<p><strong>Q: Puis-je obtenir un \u00e9tui rack qui n'est pas de profondeur standard?<\/strong><\/p>\n<p><strong>bo\u00eete de toit dure(2)<\/strong> Oui, nous faisons souvent <strong>bo\u00eetiers de montage de rack de profondeur personnalis\u00e9s<\/strong> pour les clients utilisant des planches plus longues ou des \u00e9quipements sp\u00e9ciaux.<\/p>","protected":false},"excerpt":{"rendered":"<p>If you\u2019ve ever tried to build or organize a rack of servers, you\u2019ve probably run into that mysterious letter \u201cU.\u201d It pops up everywhere \u2014 1U, 2U, 4U \u2014 and everyone in IT seems to assume you just know what it means. But if you\u2019re new to rack systems, the term can be confusing. So [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4854,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-4860","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.yifuproducts.com\/fr\/wp-json\/wp\/v2\/posts\/4860","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yifuproducts.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.yifuproducts.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.yifuproducts.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yifuproducts.com\/fr\/wp-json\/wp\/v2\/comments?post=4860"}],"version-history":[{"count":3,"href":"https:\/\/www.yifuproducts.com\/fr\/wp-json\/wp\/v2\/posts\/4860\/revisions"}],"predecessor-version":[{"id":4862,"href":"https:\/\/www.yifuproducts.com\/fr\/wp-json\/wp\/v2\/posts\/4860\/revisions\/4862"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.yifuproducts.com\/fr\/wp-json\/wp\/v2\/media\/4854"}],"wp:attachment":[{"href":"https:\/\/www.yifuproducts.com\/fr\/wp-json\/wp\/v2\/media?parent=4860"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.yifuproducts.com\/fr\/wp-json\/wp\/v2\/categories?post=4860"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.yifuproducts.com\/fr\/wp-json\/wp\/v2\/tags?post=4860"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}